Cold-applied coatings SIGNALIT PIVERT

Permanent Marking Products

SIGNALIT PIVERT

Easy to apply cold coating ensuring excellent daytime visibility.

ADVANTAGES SIGNALIT PIVERT

  • Easy to apply with multiple tools.
  • Very high durability and excellent adhesion: coating suitable for intersections, pedestrian crossings, logos, etc.
  • Non-aromatic solvent-based coating: preservation of user health.
  • CONDITIONS FOR USE

  • Application Pour the cold plaster with a trowel or similar template onto the area previously marked out with adhesive tape or a template. When the product is dry, remove the adhesive tape or template.Can also be applied with an application machine.
  • Support The minimum temperature limit of the support is 10°C. Below this temperature drying will be longer and less effective.
  • Primer On new or old hydrocarbon coatings it is recommended to apply an EP Primer (150 grams/m2).
  • Retroreflexion Signalit Pivert cold coating is applied with glass beads.
  • Thinning & Cleaning If necessary add max. 1% of VG55. Do not use other thinners.For cleaning, use Veluvine VG40 thinners.
  • Storage Protected from sunlight and frost, the paint will keep for 6 months in its original packaging. The reference is the manufacturing date affixed to the packaging.
  • TECHNICAL CHARACTERISTICS

  • Colours White (RAL colours are available under the name Signalit)
  • Luminance Class LF6 (ß-value ≥ 0.80) in accordance with EN1871 Class Q3 (Qd ≥ 130 mcd.lx-1.m-2) in accordance with EN1436
  • Retro reflection Class R3 (RL ≥ 150 mcd.lx-1.m-2) in accordance with EN1436
  • Skid resistance Class S3 (≥55 SRT)
  • Viscosity Thick coating, easy to apply compounds
  • Density 1,96 g/cm3
  • Flashpoint 10°C
  • Mixing ratio 115 g of Noviper BP-30 hardener for 8 kg of coating
  • Duration of use 10 minutes at 30°C and 15 minutes at 20°C
  • Curing time between 10 and 20 minutes depending on the outside temperature
  • Composition Based on acrylic resins (PMMA)
  • Application Manual or pneumatic or airless machine
  • DOCUMENTS

    Enduit-à-froid-SIGNALIT-PIVERT-EN.pdf