Application
Manual: mark out the surface, which has to be done, with self-adhesive tape. Mix the Rolcoating and the hardener. Apply with a spatula and level the surface using a roller. Remove adhesive strips after application.
Machine: Rolcoating can be sprayed with a special airless or pneumatic application machine, equiped with 2 circuits and internal (static mixer) or external (double spray) mixing. Benox L40LV liquid is used as hardener.
Support
Clean and dry floor, new or old hydrocarbon coatings.
Primer
On dusty and absorbing surfaces or fresh bituminous surfaces, we advise to apply EP primer first.
Ground temperature limits
Minimum application temperature is 10°C.
Maximum hydrometry 80 %
Cleaning
With VG44 or VG40.
Thinning
If necessary add max. 1% de diluant VG55
Do not use other thinners.
Storage
Protected from sunlight and frost, the paint will keep for 6 months in its original packaging. The reference is the manufacturing date affixed to the packaging.